instability_detector#
- class ansys.fluent.core.generated.solver.settings_242.instability_detector.instability_detector(name=None, parent=None)#
Bases:
Group
Set Hybrid NITA instability detector controls.
Attributes
Attribute |
Summary |
---|---|
Enable instability detector for better stability. |
|
Set Courant Number limit for detection of unstable event. |
|
Set Courant Number type for detection of unstable event. |
|
Set velocity limit for detection of unstable event. |
|
Set number of outer iterations for unstable event. |
Included in:
Parent |
Summary |
---|---|
Hybrid NITA stability controls for multiphase flow. |