advanced#
Bases:
TUIMenuEnters the advanced settings menu.
Methods:
__init__(service, version, mode, path)__init__ method of TUIMenu class.
Classes:
alternate_wall_temp_formulation(service, ...)Enables/disables an alternate formulation for wall temperatures.
alternative_solver_defaults(service, ...)Enter alternative solver defaults menu.
alternative_wall_discretization(service, ...)Enable alternative wall discretization.
anisotropic_heat_flux(service, version, ...)Select the heat flux calculation methods.
anisotropic_solid_heat_transfer(service, ...)No help available.
bcd_boundedness(service, version, mode, path)Specifies the BCD scheme parameter, which controls the boundedness strength of the BCD scheme in the pressure-based solver, as described in .
bcd_scheme_type(service, version, mode, path)BCD scheme type (standard or tunable).
bcd_weights_freeze(service, version, mode, path)Enables/disables freezing of weighting coefficients of the central differencing and the upwind components of the BCD scheme.
No help available.
correction_form(service, version, mode, path)energy_numerical_noise_filter(service, ...)Enables/disables a filter to eliminate non-physical numerical noise in the energy field.
Enable limiting of reconstruction gradient for the energy equation.
enthalpy_reference_temperature(service, ...)No help available.
explicit_under_relaxation_value(service, ...)No help available.
linearized_mass_transfer_udf(service, ...)Enables/disables the use of a linearized mass transfer user-defined function (that is, the DEFINE_LINEARIZED_MASS_TRANSFER macro), as opposed to a mass transfer user-defined function (that is, the DEFINE_MASS_TRANSFER macro).
low_diffusion_central(service, version, ...)Enter the Low Diffusion Central advection scheme menu.
nci_secondary_gradient_correction(service, ...)Enter secondary gradient source menu for non-conformal interfaces.
non_reflecting_boundary_treatment(service, ...)Enter non reflecting boundary treatment using minimal pressure reflection approach menu.
retain_cell_residuals(service, version, ...)Enables/disables the retention of cell residuals for postprocessing.
retain_temporary_solver_mem(service, ...)Enables/disables the retention of temporary solver memory, which retains gradient data and makes some advanced options available for postprocessing.
secondary_gradient_limiting(service, ...)Enters the secondary gradient limiting menu.
show_all_discretization_schemes(service, ...)Enables/disables the availability of all applicable discretization schemes.
singhal_et_al_cavitation_model(service, ...)Enables/disables the availability of the Singhal et al. cavitation model option, which can then be enabled in the Multiphase Model dialog box or by using the following text command: define/phases/set-domain-properties/interaction-domain/heat-mass-reaction/cavitation/cavitation?.
skewness_correction_enhanced(service, ...)Enable enhanced skewness correction scheme.
Enable alternative treatment for turbulent flows using walls with specified zero shear.
transient_frame_motion_numerics(service, ...)Enable time-step independent continuity discretization for transient cases with frame motion.
turbomachinery_specific_numerics(service, ...)Enter turbomachinery-specific numerics menu.
volume_flux_for_single_phase(service, ...)Enable/disable volume flux formulation for single phase flows.
__init__ method of TUIMenu class.
Bases:
TUIMethodEnables/disables an alternate formulation for wall temperatures.
Bases:
TUIMethodEnable alternative wall discretization.
Bases:
TUIMethodSelect the heat flux calculation methods.
Bases:
TUIMethodSpecifies the BCD scheme parameter, which controls the boundedness strength of the BCD scheme in the pressure-based solver, as described in .
Bases:
TUIMethodBCD scheme type (standard or tunable).
Bases:
TUIMethodEnables/disables freezing of weighting coefficients of the central differencing and the upwind components of the BCD scheme. This dialog command requires the iteration number, after which the BCD scheme weights are to be frozen at each timestep. Freezing the BCD weighting coefficients may help to improve convergence of the timestep iterations as described in .
Bases:
TUIMethod
Bases:
TUIMethodEnables/disables a filter to eliminate non-physical numerical noise in the energy field. Numerical noise can appear in solution fields where large variations in specific heat or combustion with phase change are present. Using the energy equation numerical noise filter increases robustness, but may make the solution slightly more diffusive. This text command is only available with the pressure-based solver.
Bases:
TUIMethodEnable limiting of reconstruction gradient for the energy equation.
Bases:
TUIMethodNo help available.
Bases:
TUIMethodNo help available.
Bases:
TUIMethodEnables/disables the use of a linearized mass transfer user-defined function (that is, the DEFINE_LINEARIZED_MASS_TRANSFER macro), as opposed to a mass transfer user-defined function (that is, the DEFINE_MASS_TRANSFER macro).
Bases:
TUIMethodEnter secondary gradient source menu for non-conformal interfaces.
Bases:
TUIMethodEnables/disables the retention of cell residuals for postprocessing.
Bases:
TUIMethodEnables/disables the retention of temporary solver memory, which retains gradient data and makes some advanced options available for postprocessing.
Bases:
TUIMethodEnables/disables the availability of all applicable discretization schemes.
Bases:
TUIMethodEnables/disables the availability of the Singhal et al. cavitation model option, which can then be enabled in the Multiphase Model dialog box or by using the following text command: define/phases/set-domain-properties/interaction-domain/heat-mass-reaction/cavitation/cavitation?.
Bases:
TUIMethodEnable enhanced skewness correction scheme.
Bases:
TUIMethodEnable alternative treatment for turbulent flows using walls with specified zero shear.
Bases:
TUIMethodEnable time-step independent continuity discretization for transient cases with frame motion.
Bases:
TUIMethodEnable/disable volume flux formulation for single phase flows.