heat_exchanger#
Bases:
TUIMenuEnters the heat exchanger menu.
Methods:
__init__(service, version, mode, path)__init__ method of TUIMenu class.
Classes:
dual_cell_model(service, version, mode, path)Enters the dual cell model menu.
macro_model(service, version, mode, path)Enters the heat macro-model menu.
__init__ method of TUIMenu class.
Bases:
TUIMenuEnters the dual cell model menu.
Methods:
__init__(service, version, mode, path)__init__ method of TUIMenu class.
Classes:
add_heat_exchanger(service, version, mode, path)Adds heat-exchanger.
alternative_formulation(service, version, ...)Enables/disables alternative formulation for heat transfer calculations.
delete_heat_exchanger(service, version, ...)Deletes heat-exchanger.
heat_exchanger(service, version, mode, path)Enables/disables the dual cell heat-exchanger model.
modify_heat_exchanger(service, version, ...)Modifies heat-exchanger.
plot_NTU(service, version, mode, path)Plots NTU vs.
write_NTU(service, version, mode, path)Writes NTU vs.
__init__ method of TUIMenu class.
Bases:
TUIMethodAdds heat-exchanger.
Bases:
TUIMethodEnables/disables alternative formulation for heat transfer calculations.
Bases:
TUIMethodDeletes heat-exchanger.
Bases:
TUIMethodEnables/disables the dual cell heat-exchanger model.
Bases:
TUIMethodModifies heat-exchanger.
Bases:
TUIMethodPlots NTU vs. primary mass flow rate for each auxiliary mass flow rate.
Bases:
TUIMethodWrites NTU vs. primary mass flow rate for each auxiliary mass flow rate.
Bases:
TUIMenuEnters the heat macro-model menu.
Methods:
__init__(service, version, mode, path)__init__ method of TUIMenu class.
Classes:
delete_heat_exchanger_group(service, ...)Deletes heat-exchanger group.
heat_exchanger(service, version, mode, path)Enables/disables heat-exchanger model.
heat_exchanger_group(service, version, mode, ...)Defines heat-exchanger group.
heat_exchanger_macro_report(service, ...)Reports the computed values of heat rejection, outlet temperature, and inlet temperature for the macroscopic cells (macros) in a heat exchanger.
heat_exchanger_model(service, version, mode, ...)Defines heat-exchanger core model.
heat_exchanger_report(service, version, ...)Reports the computed values of total heat rejection, outlet temperature, and inlet temperature for a specified heat-exchanger core.
heat_exchanger_zone(service, version, mode, path)Specifies the zone that represents the heat exchanger, the dimensions of the heat exchanger, the macro grid, and the coolant direction and properties.
plot_NTU(service, version, mode, path)Plots NTU vs.
write_NTU(service, version, mode, path)Writes NTU vs.
__init__ method of TUIMenu class.
Bases:
TUIMethodDeletes heat-exchanger group.
Bases:
TUIMethodEnables/disables heat-exchanger model.
Bases:
TUIMethodDefines heat-exchanger group.
Bases:
TUIMethodReports the computed values of heat rejection, outlet temperature, and inlet temperature for the macroscopic cells (macros) in a heat exchanger.
Bases:
TUIMethodDefines heat-exchanger core model.
Bases:
TUIMethodReports the computed values of total heat rejection, outlet temperature, and inlet temperature for a specified heat-exchanger core.
Bases:
TUIMethodSpecifies the zone that represents the heat exchanger, the dimensions of the heat exchanger, the macro grid, and the coolant direction and properties.
Bases:
TUIMethodPlots NTU vs. primary mass flow rate for each auxiliary mass flow rate.
Bases:
TUIMethodWrites NTU vs. primary mass flow rate for each auxiliary mass flow rate.