explicit_expert_options#
Bases:
TUIMenu
Enters the menu to set explicit VOF expert options.
Methods:
solve_vof_every_iter
(*args, **kwargs)If you enter yes, the volume fraction equations will be solved every iteration.
sub_time_step_method
(*args, **kwargs)Selects the sub-time step method.
Classes:
volume_fraction_filtering
(path, service)Enters the volume fraction filtering menu.
If you enter yes, the volume fraction equations will be solved every iteration. By default, the volume fraction equations will be solved only once per time step.
Selects the sub-time step method.
Bases:
TUIMenu
Enters the volume fraction filtering menu.
Methods:
enable
(*args, **kwargs)Enables/disables the volume fraction filtering treatment.
filtering_options
(*args, **kwargs)Selects the volume fraction filtering method.
vol_frac_cutoff
(*args, **kwargs)Specifies a cut-off value for the volume fraction filtering.
Enables/disables the volume fraction filtering treatment.
Selects the volume fraction filtering method. This command becomes available once the define/models/multiphase/explicit-expert-options/volume-fraction-filtering/enable? text option has been set to yes.